DRAFT
TM 5-4210-249-13&P-3
FIELD LEVEL MAINTENANCE
PUMP OPERATOR'S PANEL FOAM LEVEL GAUGE REPLACEMENT
INITIAL SETUP:
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Tools and Special Tools
Equipment Conditions
Tool Kit, General Mechanic's: Automotive
Batteries disconnected (TM 9-2320-325-14&P)
(WP 0622, Item 27)
Pump operator's panel housing opened
Materials/Parts
Tags, Identification (WP 0625, Item 51)
Ties, Cable, Plastic (WP 0625, Item 58)
REMOVAL
TFFT00594
NOTE
Both foam level gauges are replaced the same way.
Tag and mark connectors prior to removal to ensure proper installation.
Remove cable ties as needed.
1.
Disconnect three connectors (1).
2.
Remove four screws (2) and foam level gauge (3) from pump operator's panel (4).
END OF TASK
0322-1