PUMP OPERATOR'S PANEL ENGINE DIAGNOSTICS PLUG REPLACEMENT
INITIAL SETUP:
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Tools and Special Tools
References
Tool Kit, General Mechanic's: Automotive
WP 0615, Fig. 56
(WP 0622, Item 27)
Equipment Conditions
Materials/Parts
Batteries disconnected (TM 9-2320-325-14&P)
Tags, Identification (WP 0625, Item 51)
Pump operator's panel housing opened
Locknut (1)
(WP 0325)
Locknut (3)
REMOVAL
TFFT00592
1.
Loosen two screws (1).
2.
Remove protective sleeve (2) from pump engine diagnostics plug (3).
3.
Remove cap (4) from pump engine diagnostics plug (3).
4.
Remove locknut (5), screw (6), and cable (7) from pump engine diagnostics plug (3) and pump panel (8).
Discard locknut.
5.
Remove three locknuts (9) and screws (10) from pump engine diagnostics plug (3) and pump panel (8).
Discard locknut.
6.
Close pump operator's panel housing (WP 0325)
NOTE
Tag and mark wires prior to removal to ensure proper installation.
7.
Using extractor tool, remove six wires (11) from pump engine diagnostics plug (3).
8.
Remove screw (12) and cable (7) from cap (4).
END OF TASK