DRAFT
TM 5-4210-249-13&P-3
0322
INSTALLATION
TFFT00594
1.
Install foam level gauge (3) on pump operator's panel (4) with four screws (2).
NOTE
Install cable ties as needed.
2.
Connect three connectors (1).
END OF TASK
FOLLOW-ON MAINTENANCE
1.
Close pump operator's panel housing (WP 0325)
2.
Connect batteries (TM 9-2320-325-14&P)
END OF TASK
END OF WORK PACKAGE