PUMP OPERATOR'S PANEL FUEL GAUGE REPLACEMENT
PUMP OPERATOR'S PANEL HOURMETER REPLACEMENT

Maintenance Manual For Tactical Fire Fighting Truck (Tfft) Model M1142 - 3 Page Navigation
  115    116    117    118    119  120  121    122    123    124    125  
img
.
DRAFT
TM 5-4210-249-13&P-3
0323
INSTALLATION
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
TFFT00378
NOTE
Install fuel gauge as noted prior to removal.
1.
Install fuel gauge (2) on pump operator's panel (8) with bracket (7), two lockwashers (6), and nuts (5).
2.
Install three wires (4) on fuel gauge (2) with three nuts (3).
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
WARNING
ICON 30, 44, 27
Adhesives, solvents, and sealing compounds can burn easily, can give off harmful
vapors, and are harmful to skin and clothing. To avoid injury or death, keep away
from open fire and use in well-ventilated area. If adhesive, solvent, or sealing
compound gets on skin or clothing, wash immediately with soap and water.
3.
Apply electrical sealant to ends of three wires (4) and nuts (3).
4.
Install light (1) in fuel gauge (2).
END OF TASK
FOLLOW-ON MAINTENANCE
1.
Close pump operator's panel housing (WP 0325)
2.
Connect batteries (TM 9-2320-325-14&P)
END OF TASK
END OF WORK PACKAGE
0323-2