DRAFT
TM 5-4210-249-13&P-3
FIELD LEVEL MAINTENANCE
PUMP OPERATOR'S PANEL HOURMETER REPLACEMENT
INITIAL SETUP:
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Tools and Special Tools
References
Tool Kit, General Mechanic's: Automotive
WP 0615, Fig. 56
(WP 0622, Item 27)
Equipment Conditions
Materials/Parts
Batteries disconnected (TM 9-2320-325-14&P)
Adhesive, RTV 732 (WP 0625, Item 2)
Pump operator's panel housing
Tags, Identification (WP 0625, Item 51)
REMOVAL
TFFT00680
NOTE
Tag and mark wires prior to removal to ensure proper installation.
1.
Remove two nuts (1) and wires (2) from hour meter (3).
2.
Remove two wires (4) from hour meter (3).
3.
Remove two screws (5), bracket (6), and hour meter (3) from pump operator's panel (7).
END OF TASK
0324-1