PUMP OPERATOR'S PANEL HOURMETER REPLACEMENT - Continued
PUMP OPERATOR'S PANEL HOUSING OPEN/CLOSE - Continued

Maintenance Manual For Tactical Fire Fighting Truck (Tfft) Model M1142 - 3 Page Navigation
  118    119    120    121    122  123  124    125    126    127    128  
img
.
DRAFT
TM 5-4210-249-13&P-3
0325
FIELD LEVEL MAINTENANCE
PUMP OPERATOR'S PANEL HOUSING OPEN/CLOSE
INITIAL SETUP:
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Tools and Special Tools
References
Tool Kit, General Mechanic's: Automotive
WP 0615, Fig. 47
(WP 0622, Item 27)
Equipment Conditions
Materials/Parts
Pump operator's panel cover opened (WP 0019)
Lockwasher (2)
OPEN
TFFT00358
1.
Remove two screws (1) and manual metering valve handle (2) from manual foam valve (3).