PUMP HOUSE DISTRIBUTION BOX RELAY REPLACEMENT - Continued
PUMP HOUSE COOLING FAN TEMPERATURE SWITCH REPLACEMENT - Continued

Maintenance Manual For Tactical Fire Fighting Truck (Tfft) Model M1142 - 3 Page Navigation
  400    401    402    403    404  405  406    407    408    409    410  
img
. . .
DRAFT
TM 5-4210-249-13&P-3
0414
FIELD LEVEL MAINTENANCE
PUMP HOUSE COOLING FAN TEMPERATURE SWITCH REPLACEMENT
INITIAL SETUP:
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Tools and Special Tools
References
Tool Kit, General Mechanic's: Automotive
WP 0615, Fig. 80, 123
(WP 0622, Item 27)
Equipment Conditions
Materials/Parts
Pump house panel T removed (WP 0540)
Adhesive, RTV 732 (WP 0625, Item 2)
Pump operator's panel housing opened
Tags, Identification (WP 0625, Item 51)
(WP 0325)
REMOVAL
TFFT01053
NOTE
Tag and mark wires prior to removal to ensure proper installation.
1.
Remove two nuts (1) and wires (2) from pump house cooling fan temperature switch (3).
2.
Remove nut (4) and pump house cooling fan temperature switch (3) from frame rail (5).
END OF TASK