DRAFT
TM 5-4210-249-13&P-3
FIELD LEVEL MAINTENANCE
PUMP HOUSE COOLING FAN TEMPERATURE SWITCH REPLACEMENT
INITIAL SETUP:
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Tools and Special Tools
References
Tool Kit, General Mechanic's: Automotive
WP 0615, Fig. 80, 123
(WP 0622, Item 27)
Equipment Conditions
Materials/Parts
Adhesive, RTV 732 (WP 0625, Item 2)
Pump operator's panel housing opened
Tags, Identification (WP 0625, Item 51)
REMOVAL
TFFT01053
NOTE
Tag and mark wires prior to removal to ensure proper installation.
1.
Remove two nuts (1) and wires (2) from pump house cooling fan temperature switch (3).
2.
Remove nut (4) and pump house cooling fan temperature switch (3) from frame rail (5).
END OF TASK
0414-1