PRESSURE TRANSDUCER REPLACEMENT
PUMP HOUSE DISTRIBUTION BOX CIRCUIT BREAKER REPLACEMENT

Maintenance Manual For Tactical Fire Fighting Truck (Tfft) Model M1142 - 3 Page Navigation
  395    396    397    398    399  400  401    402    403    404    405  
img
.
DRAFT
TM 5-4210-249-13&P-3
0411
INSTALLATION
TFFT00053
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
WARNING
ICON 30, 44, 27
Adhesives, solvents, and sealing compounds can burn easily, can give off harmful
vapors, and are harmful to skin and clothing. To avoid injury or death, keep away
from open fire and use in well-ventilated area. If adhesive, solvent, or sealing
compound gets on skin or clothing, wash immediately with soap and water.
1.
Apply sealing compound to threads of transducer (2).
2.
Install transducer (2) on elbow (3).
3.
Connect connector (1) on transducer (2).
END OF TASK
FOLLOW-ON MAINTENANCE
Close pump house panel A (WP 0539)
END OF TASK
END OF WORK PACKAGE