DRAFT
TM 5-4210-249-13&P-3
FIELD LEVEL MAINTENANCE
PUMP HOUSE HEATER DIAGNOSTIC MODULE REPLACEMENT
INITIAL SETUP:
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Tools and Special Tools
Materials/Parts
Tool Kit, General Mechanic's: Automotive
Locknut (2)
(WP 0622, Item 27)
Lockwasher (2)
Materials/Parts
References
Compound, Sealing (WP 0625, Item 17)
Tags, Identification (WP 0625, Item 51)
WP 0615, Fig. 173
Ties, Cable, Plastic (WP 0625, Item 58)
Equipment Conditions
Lockwasher (1)
Batteries disconnected (TM 9-2320-325-14&P)
Locknut (1)
Locknut (2)
REMOVAL
TFFT04651
NOTE
Remove cable ties as required.
Tag and mark wires prior to removal to ensure proper installation.
1.
Disconnect heater diagnostic module connector (1) from pump house wire harness connector (2).
NOTE
Note position of washers prior to removal to ensure proper installation.
2.
Remove two screws (3), box (4), and two washers (5) from frame rail (6).
3.
0415-1