AUDIO ALARM REPLACEMENT
PUMP OPERATOR'S PANEL COVER REPLACEMENT

Maintenance Manual For Tactical Fire Fighting Truck (Tfft) Model M1142 - 3 Page Navigation
  105    106    107    108    109  110  111    112    113    114    115  
img
.
DRAFT
TM 5-4210-249-13&P-3
0319
INSTALLATION
TFFT00316
NOTE
Both audio alarms are installed the same way.
1.
Install audio alarm (3) on pump operator's panel (4) with retainer (2).
2.
Connect connector (1).
END OF TASK
FOLLOW-ON MAINTENANCE
1.
Close pump operator's panel housing (WP 0325)
2.
Connect batteries (TM 9-2320-325-14&P)
END OF TASK
END OF WORK PACKAGE