DIRECT TANK FILL VALVE DOES NOT OPERATE PROPERLY (AUTO OR MANUAL MODE) - Continued
DIRECT TANK FILL VALVE DOES NOT OPERATE PROPERLY (AUTO OR MANUAL MODE) - Continued

Maintenance Manual For Tactical Fire Fighting Truck (Tfft) Model M1142 - 1 Page Navigation
  676    677    678    679    680  681  682    683    684    685    686  
img
.
DRAFT
TM 5-4210-249-13&P-1
0105
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
TFFT02787
Step 14.
Put pump operator's panel DIRECT TANK FILL switch to AUTO position (WP 0004).
With a test lead set, check for 22 to 28 VDC between pump house power distribution
wire harness wire 2329 (blue) at relay P1 connector, terminal 3 and a known good
ground.
If 22 to 28 VDC are not present, go to Step 19.
0105-12