DIRECT TANK FILL VALVE DOES NOT OPERATE PROPERLY (AUTO OR MANUAL MODE) - Continued
DIRECT TANK FILL VALVE DOES NOT OPERATE PROPERLY (AUTO OR MANUAL MODE) - Continued

Maintenance Manual For Tactical Fire Fighting Truck (Tfft) Model M1142 - 1 Page Navigation
  672    673    674    675    676  677  678    679    680    681    682  
img
DRAFT
TM 5-4210-249-13&P-1
0105
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
TFFT02783
Step 9.
With a test lead set, check for continuity across pump house power distribution wire
harness wire 2325 (black) from relay P2 connector, terminal 3 to relay P1 connector,
terminal 1.
If there is no continuity, replace pump house power distribution wire harness
and block (WP 0457).
0105-8