DIRECT TANK FILL VALVE DOES NOT OPERATE PROPERLY (AUTO OR MANUAL MODE) - Continued
DIRECT TANK FILL VALVE DOES NOT OPERATE PROPERLY (AUTO OR MANUAL MODE) - Continued

Maintenance Manual For Tactical Fire Fighting Truck (Tfft) Model M1142 - 1 Page Navigation
  681    682    683    684    685  686  687    688    689    690    691  
img
DRAFT
TM 5-4210-249-13&P-1
0105
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
TFFT02791
Step 20.
Disconnect pump operator's panel wire harness pump house power distribution wire
harness connector DP2. With a test lead set, check for continuity across wire 2316
(brown) from pump operator's panel DIRECT TANK FILL switch, terminal wire 2316 to
pump operator's panel wire harness pump house power distribution wire harness
connector DP2, terminal S.
a.
If there is continuity, repair wire 2316 in pump house power distribution
wire harness if repairable (TM 9-2320-325-14&P), or replace pump
house power distribution wire harness and block (WP 0457).
b.
If there is continuity, repair wire 2316 in pump operator's panel wire
harness if repairable (TM 9-2320-325-14&P), or replace pump
operator's panel wire harness (WP 0459).
0105-17