DIRECT TANK FILL VALVE DOES NOT OPERATE PROPERLY (AUTO OR MANUAL MODE) - Continued
DIRECT TANK FILL VALVE DOES NOT OPERATE PROPERLY (AUTO OR MANUAL MODE) - Continued

Maintenance Manual For Tactical Fire Fighting Truck (Tfft) Model M1142 - 1 Page Navigation
  677    678    679    680    681  682  683    684    685    686    687  
img
. .
DRAFT
TM 5-4210-249-13&P-1
0105
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
TFFT02788
WARNING
ICON 3
Remove rings, wristwatches, neck chains, and any other jewelry before working
around vehicle. Jewelry can catch on equipment and cause serious injury. Jewelry
and tools may short across electrical circuits and cause damage to equipment, or
severe burns or electrical shock to personnel.
NOTE
Steps (15) through (18) will isolate fault to a faulty relay. Perform Steps as written,
replacing relays when instructed, to ensure faulty relay is located.
Step 15.
Turn battery disconnect switch to OFF position (WP 0007). Install relay P2 (WP 0413).
Turn battery disconnect switch to ON position (WP 0007). With a test lead set, check
for 22 to 28 VDC between pump house power distribution wire harness wire 2325
(black) at relay P1 connector, terminal 1 and a known good ground.
If 22 to 28 VDC are not present, install relay P1 and replace relay
P2 (WP 0413).