• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
DIRECT TANK FILL VALVE DOES NOT OPERATE PROPERLY (AUTO OR MANUAL MODE) - Continued
DIRECT TANK FILL VALVE DOES NOT OPERATE PROPERLY (AUTO OR MANUAL MODE) - Continued

Maintenance Manual For Tactical Fire Fighting Truck (Tfft) Model M1142 - 1 Page Navigation
  671    672    673    674    675  676  677    678    679    680    681  
img
DRAFT
TM 5-4210-249-13&P-1
0105
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
TFFT02782
Step 8.
With a test lead set, check for continuity across pump house power distribution wire
harness wire 2328 (green) from relay P2 connector, terminal 2 to relay P3 connector,
terminal 3.
If there is no continuity, replace pump house power distribution wire harness
and block (WP 0457).
0105-7


Privacy Statement
Press Release
Contact

© Copyright Integrated Publishing, Inc.. All Rights Reserved.