CYLINDER HEAD REMOVAL/INSTALLATION - Continued
CYLINDER HEAD REMOVAL/INSTALLATION - Continued

Maintenance Manual for Firefighting Truck, 100 Ft Aerial Ladder, 1000 GPM Page Navigation
  74    75    76    77    78  79  80    81    82    83    84  
img
. .
TM 5-4210-233-14&P-2
6-13. CYLINDER HEAD REMOVAL/INSTALLATION - Continued
b. Cleaning and Inspection.
WARNING
Dry cleaning solvent P-D-680 is potentially
dangerous. Avoid repeated and prolonged
breathing of vapors and skin contact with the
liquid. Do not use near open flame, arcing
equipment or other ignition sources. Always
wear eye protection and protective clothing.
The flash point of P-D-680 is 100 to 138 deg. F
(38 to 59 deg. C).
(1)
Clean cylinder head (1) with dry cleaning solvent
(Item 3, Appendix E).
WARNING
Compressed air used for cleaning purposes will not exceed 30 psi
(207 kPa). Use only with effective chip guarding and personal
protective equipment (goggles/shield, gloves, etc.).
(2)
Dry cylinder head (1) with compressed air.
(3)
Inspect cylinder head mounting surface to be sure
it is clean and free from burrs.
(4)
Inspect push rod ends (2) to be sure they are
threaded into clevis (3) until end of push rod
projects through clevis.
(5)
Clean cylinder block head gasket surface with dry
cleaning solvent (Item 3, Appendix E).
(6)
Dry cylinder block head gasket surface with
compressed air.
6-81