DRAFT
TM 5-4210-249-13&P-4
FIELD LEVEL MAINTENANCE
HYDRAULIC GENERATOR RESERVOIR TEMPERATURE SENSOR REPLACEMENT
INITIAL SETUP:
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Tools and Special Tools
References
Tool Kit, General Mechanic's: Automotive
Equipment Conditions
Materials/Parts
Hydraulic generator reservoir drained (WP 0588)
Compound, Sealing, Pipe
REMOVAL
TFFT00607
NOTE
Note position and remove cable ties and cushion clips as required.
1.
Disconnect connector (1).
2.
Remove plug (2) from hydraulic reservoir (3).
3.
Remove hydraulic temperature sensor (4) from plug (2).
END OF TASK
0598-1