HYDRAULIC GENERATOR RESERVOIR STRAINER REPLACEMENT - Continued
HYDRAULIC GENERATOR RESERVOIR TEMPERATURE SENSOR REPLACEMENT - Continued

Maintenance Manual For Tactical Fire Fighting Truck (Tfft) Model M1142 - 4 Page Navigation
  194    195    196    197    198  199  200    201    202    203    204  
img
. . . . . .
DRAFT
TM 5-4210-249-13&P-4
0598
FIELD LEVEL MAINTENANCE
HYDRAULIC GENERATOR RESERVOIR TEMPERATURE SENSOR REPLACEMENT
INITIAL SETUP:
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Tools and Special Tools
References
Tool Kit, General Mechanic's: Automotive
WP 0615, Fig. 178
(WP 0622, Item 27)
Equipment Conditions
Materials/Parts
Hydraulic generator reservoir drained (WP 0588)
Compound, Sealing, Pipe
Thread (WP 0625, Item 21)
Ties, Cable, Plastic (WP 0625, Item 58)
REMOVAL
TFFT00607
NOTE
Note position and remove cable ties and cushion clips as required.
1.
Disconnect connector (1).
2.
Remove plug (2) from hydraulic reservoir (3).
3.
Remove hydraulic temperature sensor (4) from plug (2).
END OF TASK
0598-1