HYDRAULIC GENERATOR RESERVOIR REPLACEMENT - Continued
HYDRAULIC GENERATOR RESERVOIR STRAINER REPLACEMENT - Continued

Maintenance Manual For Tactical Fire Fighting Truck (Tfft) Model M1142 - 4 Page Navigation
  192    193    194    195    196  197  198    199    200    201    202  
img
. . . .
DRAFT
TM 5-4210-249-13&P-4
0597
FIELD LEVEL MAINTENANCE
HYDRAULIC GENERATOR RESERVOIR STRAINER REPLACEMENT
INITIAL SETUP:
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Tools and Special Tools
References
Tool Kit, General Mechanic's: Automotive
WP 0615, Fig. 178
(WP 0622, Item 27)
Equipment Conditions
Materials/Parts
Hydraulic reservoir breather removed (WP 0594)
Lockwasher (6)
REMOVAL
TFFT00674
1.
Remove six screws (1), lockwashers (2), filler neck (3), and gasket (4) from hydraulic reservoir (5). Discard
lockwashers.
2.
Remove strainer (6) and gasket (7) from hydraulic reservoir (5).
END OF TASK