HYDRAULIC GENERATOR RESERVOIR REPLACEMENT
HYDRAULIC GENERATOR RESERVOIR REPLACEMENT - Continued

Maintenance Manual For Tactical Fire Fighting Truck (Tfft) Model M1142 - 4 Page Navigation
  189    190    191    192    193  194  195    196    197    198    199  
img
DRAFT
TM 5-4210-249-13&P-4
0596
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
TFFT0573A
NOTE
Screws are located in hose compartment.
3.
Remove two nuts (3), lockwashers (4), four washers (5), and two screws (6) from two brackets (7) and vehicle.
Discard lockwashers.
4.
Remove hydraulic reservoir (8) from vehicle.
5.
Remove two screws (9), lockwashers (10), washers (11), brackets (7), and rubber grommets (12) from
hydraulic reservoir (8). Discard lockwashers.
6.
Remove fitting (2) from hydraulic reservoir (8).
TFFT0573B
7.
Remove two screws (13) and rubber grommet (14) from hydraulic reservoir (8).
8.
Remove two plugs (15) and (16) from hydraulic reservoir (8).
END OF TASK