HYDRAULIC GENERATOR RESERVOIR FLUID LEVEL GAUGE REPLACEMENT - Continued
HYDRAULIC GENERATOR RESERVOIR REPLACEMENT - Continued

Maintenance Manual For Tactical Fire Fighting Truck (Tfft) Model M1142 - 4 Page Navigation
  188    189    190    191    192  193  194    195    196    197    198  
img
. . . . . . . .
DRAFT
TM 5-4210-249-13&P-4
0596
FIELD LEVEL MAINTENANCE
HYDRAULIC GENERATOR RESERVOIR REPLACEMENT
INITIAL SETUP:
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Tools and Special Tools
Equipment Conditions
Tool Kit, General Mechanic's: Automotive
Hydraulic reservoir strainer removed (WP 0597)
(WP 0622, Item 27)
Hydraulic generator reservoir fluid level gauge
removed (WP 0595)
Materials/Parts
Hydraulic generator reservoir temperature sensor
Compound, Sealing, Pipe Thread
removed (WP 0598)
(WP 0625, Item 21)
Hydraulic generator reservoir boost unit assembly
Lockwasher (2)
removed (WP 0593)
Lockwasher (2)
References
WP 0015
WP 0615, Fig. 178
REMOVAL
TFFT00573
1.
Remove elbow (1) from fitting (2).
2.
Open hose bed cover (WP 0015).