DRAFT
TM 5-4210-249-13&P-4
FIELD LEVEL MAINTENANCE
HYDRAULIC GENERATOR RESERVOIR FLUID LEVEL GAUGE REPLACEMENT
INITIAL SETUP:
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Tools and Special Tools
References
Tool Kit, General Mechanic's: Automotive
Equipment Conditions
Materials/Parts
Hydraulic reservoir drained (serviced) (WP 0588)
Preformed Packing (2)
REMOVAL
TFFT00609
NOTE
Note position of hydraulic reservoir fluid level gauge prior to removal to ensure proper
installation.
1.
Remove two nuts (1) and hydraulic reservoir fluid gauge (2) from hydraulic reservoir (3).
2.
Remove two preformed packings (4) from hydraulic reservoir fluid gauge (2). Discard preformed packings.
END OF TASK
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
0595-1