HYDRAULIC GENERATOR RESERVOIR BREATHER REPLACEMENT - Continued
HYDRAULIC GENERATOR RESERVOIR FLUID LEVEL GAUGE REPLACEMENT - Continued

Maintenance Manual For Tactical Fire Fighting Truck (Tfft) Model M1142 - 4 Page Navigation
  186    187    188    189    190  191  192    193    194    195    196  
img
. . . . .
DRAFT
TM 5-4210-249-13&P-4
0595
FIELD LEVEL MAINTENANCE
HYDRAULIC GENERATOR RESERVOIR FLUID LEVEL GAUGE REPLACEMENT
INITIAL SETUP:
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Tools and Special Tools
References
Tool Kit, General Mechanic's: Automotive
WP 0615, Fig. 178
(WP 0622, Item 27)
Equipment Conditions
Materials/Parts
Hydraulic reservoir drained (serviced) (WP 0588)
Preformed Packing (2)
Hydraulic oil filter base removed (WP 0590)
REMOVAL
TFFT00609
NOTE
Note position of hydraulic reservoir fluid level gauge prior to removal to ensure proper
installation.
1.
Remove two nuts (1) and hydraulic reservoir fluid gauge (2) from hydraulic reservoir (3).
2.
Remove two preformed packings (4) from hydraulic reservoir fluid gauge (2). Discard preformed packings.
END OF TASK
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
0595-1