WATER PUMP ENGINE COOLING SYSTEM SERVICE - Continued
WATER PUMP ENGINE COOLANT TEMPERATURE SENSOR REPLACEMENT

Maintenance Manual For Tactical Fire Fighting Truck (Tfft) Model M1142 - 3 Page Navigation
  854    855    856    857    858  859  860    861    862    863    864  
img
.
DRAFT
TM 5-4210-249-13&P-3
0479
NOTE
If using corrosion inhibitor, add it to radiator first, then add coolant.
5.
Fill radiator (2) with approximately 17.25 qt. (16.3 l) of coolant, up to the maximum marking or fill-up limit.
6.
Tighten engine oil cooler duct screw (6) to 13 lb-ft (18 Nm).
7.
Install preformed packing (10) and vent plug (9) on radiator (2), and tighten vent plug (9) to 30 lb-ft (40 Nm).
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
TFFT00768A
8.
Tighten drain plug (3) on radiator (2).
9.
Install radiator cap (1) on radiator (2).
END OF TASK
FOLLOW-ON MAINTENANCE
1.
Connect batteries (TM 9-2320-325-14&P)
2.
Install pump house panel G (WP 0540)
END OF TASK
END OF WORK PACKAGE