FOAM TANK LEVEL PROBE WIRE HARNESS REPLACEMENT - Continued
INLET, DISCHARGE, AND TANK FILL AND RE-CIRCULATING CONTROL VALVE WIRE HARNESS REPLACEMENT - Continued

Maintenance Manual For Tactical Fire Fighting Truck (Tfft) Model M1142 - 3 Page Navigation
  626    627    628    629    630  631  632    633    634    635    636  
img
. . . . . . .
DRAFT
TM 5-4210-249-13&P-3
0453
FIELD LEVEL MAINTENANCE
INLET, DISCHARGE, AND TANK FILL AND RE-CIRCULATING CONTROL VALVE WIRE HARNESS
REPLACEMENT
INITIAL SETUP:
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Equipment Conditions (continued)
Tools and Special Tools
Pump house panel G removed (for No. 3 and
Tool Kit, General Mechanic's: Automotive
No. 4 passenger side discharge valve power
(WP 0622, Item 27)
supply wire harnesses (WP 0540)
Materials/Parts
Pump house panel I removed (for driver side
Ties, Cable, Plastic (WP 0625, Item 58)
pre-connect A valve power supply wire
harness) (WP 0540)
References
Close pump house access door (for passenger
WP 0615, Fig. 56
side inlet valve power supply wire harness, if
opened) (WP 0539)
Equipment Conditions
Remove pump house panel M (for passenger side
Pump house panel A opened (for No. 1 and No. 2
inlet valve power supply wire harness)
driver side discharge, tank fill and
(WP 0540)
re-circulating, and driver main inlet valve
Pump operator's panel housing
power supply wire harnesses (WP 0539)
opened (WP 0325)
NOTE
No. 1 and No. 2 driver side discharge, tank fill and re-circulating, and driver main inlet
valve power supplies are accessed by opening pump house panel A.
No. 3 and No. 4 passenger side discharge and driver side pre-connect B valve power
supplies are accessed by removing pump house panel G.
Driver side pre-connect A valve power supply is accessed by removing pump house I,
located on driver side by transmission.
Passenger side auxiliary inlet valve power supply is accessed by removing pump house
panel M or pump house access door located below pump house panel J. (Orientation of
valve may vary.)