DRAFT
TM 5-4210-249-13&P-3
FIELD LEVEL MAINTENANCE
INLET, DISCHARGE, AND TANK FILL AND RE-CIRCULATING CONTROL VALVE WIRE HARNESS
REPLACEMENT
INITIAL SETUP:
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Equipment Conditions (continued)
Tools and Special Tools
Pump house panel G removed (for No. 3 and
Tool Kit, General Mechanic's: Automotive
No. 4 passenger side discharge valve power
(WP 0622, Item 27)
Materials/Parts
Pump house panel I removed (for driver side
Ties, Cable, Plastic (WP 0625, Item 58)
pre-connect A valve power supply wire
References
Close pump house access door (for passenger
WP 0615, Fig. 56
side inlet valve power supply wire harness, if
Equipment Conditions
Remove pump house panel M (for passenger side
Pump house panel A opened (for No. 1 and No. 2
inlet valve power supply wire harness)
driver side discharge, tank fill and
re-circulating, and driver main inlet valve
Pump operator's panel housing
NOTE
No. 1 and No. 2 driver side discharge, tank fill and re-circulating, and driver main inlet
valve power supplies are accessed by opening pump house panel A.
No. 3 and No. 4 passenger side discharge and driver side pre-connect B valve power
supplies are accessed by removing pump house panel G.
Driver side pre-connect A valve power supply is accessed by removing pump house I,
located on driver side by transmission.
Passenger side auxiliary inlet valve power supply is accessed by removing pump house
panel M or pump house access door located below pump house panel J. (Orientation of
valve may vary.)
0453-1