FLOW SENSOR WIRE HARNESS REPLACEMENT - Continued
FOAM TANK LEVEL PROBE WIRE HARNESS REPLACEMENT - Continued

Maintenance Manual For Tactical Fire Fighting Truck (Tfft) Model M1142 - 3 Page Navigation
  623    624    625    626    627  628  629    630    631    632    633  
img
. .
DRAFT
TM 5-4210-249-13&P-3
0452
FIELD LEVEL MAINTENANCE
FOAM TANK LEVEL PROBE WIRE HARNESS REPLACEMENT
INITIAL SETUP:
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Tools and Special Tools
References
Tool Kit, General Mechanic's: Automotive
WP 0615, Fig. 51
(WP 0622, Item 27)
Equipment Conditions
Materials/Parts
Hose bed cover opened (WP 0015)
Tags, Identification (WP 0625, Item 51)
Pump operator's panel housing
Ties, Cable, Plastic (WP 0625, Item 58)
opened (WP 0325)
REMOVAL
TFFT03318
NOTE
Both foam probe wire harnesses are removed the same way. Foam A probe wire harness
shown.
Note routing of foam A probe wire harness prior to removal to ensure proper installation.
Note position and remove cable ties, split looms, and cushion clips as required.
1.
Remove four screws (1), washers (2), and cover (3) from hose bed (4).
2.
Disconnect foam probe wire harness connector (5) from foam probe connector (6).