TM 5-4210-249-13&P-3
0451
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
TFFT03245
3.
Connect No. 3 passenger side flow sensor gauge connector (1) to No. 3 passenger side flow sensor wire
harness connector (2).
FOLLOW-ON MAINTENANCE
1.
Close pump operator's panel housing (WP 0325)
2.
Install pump house panel I (Driver side pre-connect A flow sensor wire harness) (WP 0540)
3.
Install pump house panel G (Driver side pre-connect B, No. 3 and No. 4 passenger side discharge flow sensor
4.
Close pump house panel A (No. 1 and No. 2 driver side discharge flow sensor wire harnesses) (WP 0539)
END OF TASK
END OF WORK PACKAGE
0451-4