FLOW SENSOR WIRE HARNESS REPLACEMENT - Continued
FOAM TANK LEVEL PROBE WIRE HARNESS REPLACEMENT

Maintenance Manual For Tactical Fire Fighting Truck (Tfft) Model M1142 - 3 Page Navigation
  622    623    624    625    626  627  628    629    630    631    632  
img
. . . .
DRAFT
TM 5-4210-249-13&P-3
0451
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
TFFT03245
3.
Connect No. 3 passenger side flow sensor gauge connector (1) to No. 3 passenger side flow sensor wire
harness connector (2).
FOLLOW-ON MAINTENANCE
1.
Close pump operator's panel housing (WP 0325)
2.
Install pump house panel I (Driver side pre-connect A flow sensor wire harness) (WP 0540)
3.
Install pump house panel G (Driver side pre-connect B, No. 3 and No. 4 passenger side discharge flow sensor
wire harnesses) (WP 0540)
4.
Close pump house panel A (No. 1 and No. 2 driver side discharge flow sensor wire harnesses) (WP 0539)
END OF TASK
END OF WORK PACKAGE