PUMP HOUSE ACCESS DOORS REPLACEMENT - Continued
PUMP HOUSE PANEL A OPEN/CLOSE - Continued

Maintenance Manual For Tactical Fire Fighting Truck (Tfft) Model M1142 - 3 Page Navigation
  1152    1153    1154    1155    1156  1157  1158    1159    1160    1161    1162  
img
.
DRAFT
TM 5-4210-249-13&P-3
0539
FIELD LEVEL MAINTENANCE
PUMP HOUSE PANEL A OPEN/CLOSE
INITIAL SETUP:
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Tools and Special Tools
Equipment Conditions
Tool Kit, General Mechanic's: Automotive
Water pump engine OFF (WP 0022)
(WP 0622, Item 27)
Engine OFF (TM 9-2320-347-10)
Wheels chocked (TM 9-2320-347-10)
OPEN PUMP HOUSE PANEL A
TFFFT01965
1.
Release three quick release fasteners (1) and pull open pump house panel A (2).
0539-1