PUMP OPERATOR'S PANEL INDICATOR LIGHT REPLACEMENT
PUMP OPERATOR'S PANEL INDICATOR LAMP REPLACEMENT

Maintenance Manual For Tactical Fire Fighting Truck (Tfft) Model M1142 - 3 Page Navigation
  122    123    124    125    126  127  128    129    130    131    132  
img
.
DRAFT
TM 5-4210-249-13&P-3
0326
INSTALLATION
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
TFFT00362
1.
Install indicator light (3) on pump operator's panel (6) with washer (5) and nut (4).
2.
Install two wires (2) on indicator light (3) with two screws (1).
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
WARNING
ICON 30, 44, 27
Adhesives, solvents, and sealing compounds can burn easily, can give off harmful
vapors, and are harmful to skin and clothing. To avoid injury or death, keep away
from open fire and use in well-ventilated area. If adhesive, solvent, or sealing
compound gets on skin or clothing, wash immediately with soap and water.
3.
Apply electrical sealant to two wires (2) and screws (1).
END OF TASK
FOLLOW-ON MAINTENANCE
1.
Close pump operator's panel housing (WP 0325)
2.
Connect batteries (TM 9-2320-325-14&P)
END OF TASK
END OF WORK PACKAGE