FOAM SYSTEM DOES NOT OPERATE - Continued
PUMP ENGINE CRANKS BUT FAILS TO START - Continued

Maintenance Manual For Tactical Fire Fighting Truck (Tfft) Model M1142 - 1 Page Navigation
  268    269    270    271    272  273  274    275    276    277    278  
img
. . . . . .
DRAFT
TM 5-4210-249-13&P-1
0061
OPERATOR LEVEL MAINTENANCE
PUMP ENGINE CRANKS BUT FAILS TO START
INITIAL SETUP:
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
References
Equipment Conditions
WP 0004
Water pump engine OFF (WP 0022)
WP 0007
Engine OFF (TM 9-2320-347-10)
Wheels chocked (TM 9-2320-347-10)
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
PUMP ENGINE CRANKS BUT FAILS TO START
TFFT03938
Step 1.
Turn battery disconnect switch to ON position (WP 0007). Turn cab ENGINE START
switch to ON position. Check cab or pump operator's panel fuel level gauge for
presence of fuel (WP 0004).
If cab or pump operator's panel fuel level gauge indicates low fuel level, fill
fuel tank (TM 9-2320-347-10).