PUMP ENGINE RUNS ROUGH OR SHUTS DOWN WHILE RUNNING
PUMP DOES NOT PRIME

Maintenance Manual For Tactical Fire Fighting Truck (Tfft) Model M1142 - 1 Page Navigation
  273    274    275    276    277  278  279    280    281    282    283  
img
DRAFT
TM 5-4210-249-13&P-1
0063
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
TFFT04389
Step 3.
Check pump engine air cleaner intake vent for blockage.
If pump engine air cleaner intake vent is blocked, clear blockage.
Step 4.
Check pump engine cooling air vents for blockage.
a.
If pump engine air cleaner intake vents are blocked, clear blockage.
b.
If pump engine still runs rough or shuts down while running, notify
Supervisor.
END OF TASK
FOLLOW-ON MAINTENANCE
Remove wheel chocks (TM 9-2320-347-10)
END OF TASK
END OF WORK PACKAGE