WINDSHIELD DELUGE OPERATION
FOAM SYSTEM FLUSHING

Maintenance Manual For Tactical Fire Fighting Truck (Tfft) Model M1142 - 1 Page Navigation
  149    150    151    152    153  154  155    156    157    158    159  
img
. . . . . .
DRAFT
TM 5-4210-249-13&P-1
0039
OPERATOR MAINTENANCE
GROUND SWEEPS OPERATION
STARTING GROUND SWEEPS
TFFT02228
1.
Make sure crew cab roof hatch is closed and secure (WP 0018).
2.
Put TANK TO PUMP switch (1) to on position. Indicator light (2) will illuminate.
3.
Start water pump engine (WP 0022).
4.
Prime water pump (WP 0023) until pressure registers on pump discharge gauge.
5.
Set pressure governor (WP 0024).
6.
Put GROUND SWEEPS switch (3) to on position. Indicator light (4) will illuminate.
END OF TASK
STOPPING GROUND SWEEPS
1.
Put GROUND SWEEPS switch (3) to off position. Indicator light (4) will go out.
2.
Turn OFF water pump engine (WP 0022).
3.
Put TANK TO PUMP switch (1) to off position. Indicator light (2) will go out.
END OF TASK
END OF WORK PACKAGE