LOCKUP CUTOFF VALVE BODY - Continued
PRIMING TANK

Maintenance Manual for Firefighting Truck, 100 Ft Aerial Ladder, 1000 GPM Page Navigation
  376    377    378    379    380  381  382    383    384    385    386  
img
. .
d.
Assembly.
NOTE
Each valve should be installed in same bore from which valve was removed.
When dry, check that all lockup cutoff valves move freely in their bores.
Apply lubricating oil (item 1 0, Appendix E) to all parts.
(1) Apply lubricating oil to valve body (2).
(2) Install valve (12) and valve plug (1 1) in bore (13).
(3) Install retainer pin (1 0) in valve body (2).
(4) Install valve (8) and valve plug (7) in bore (9).
(5) Install retainer pin (6) in valve body (2).
(6) Install valve (4) and valve plug (3) in bore (5).
(7) Install retainer pin (1) in valve body (2).
e.
Installation. Install valve (1) with eight screws (2) in transmission (3). Torque screws to 108 to 132 lb-in. (1
2 to 1 5 N-m).
f.
Follow-on Maintenance. Install internal filter element (see para 6-54).