TORQUE CONVERTER PUMP - Continued
TORQUE CONVERTER HOUSING

Maintenance Manual for Firefighting Truck, 100 Ft Aerial Ladder, 1000 GPM Page Navigation
  269    270    271    272    273  274  275    276    277    278    279  
img
. . .
TM 5-4210-233-14&P-2
6.50. TORQUE CONVERTER PUMP - Continued
(5)
Place bearing installer tool handle (Appendix B, Section III, Item 62) over bearing installer tool.
(6)
Drive bearing (6) down until seated.
(7)
Remove bearing installer tool.
(8)
Install spacer (7) over ground sleeve (5) on pump (3).
(9)
Install retaining ring (8) on ground sleeve (5).
(10) Coat pump hub (3) and hub area (9) with lubricating oil (Item 10, Appendix E).
f.
Follow-on Maintenance.
(1)
Install torque converter stator into torque converter housing (see para 6-49).
6-276