TORQUE CONVERTER HOUSING - Continued
TORQUE CONVERTER HOUSING - Continued

Maintenance Manual for Firefighting Truck, 100 Ft Aerial Ladder, 1000 GPM Page Navigation
  272    273    274    275    276  277  278    279    280    281    282  
img
TM 5-4210-233-14&P-2
6-51. TORQUE CONVERTER HOUSING - Continued
WARNING
Serious  injury  could  occur  if  heavy  equipment  is
moved/lifted without sufficient personnel to do the job. Use
proper physical lifting procedures or use a suitable lifting
device or dolly.  Wear safety shoes, gloves and other
suitable protective cloth- ing. Area should be clear of other
personnel. Serious injury or death can result from falling
objects.
(7)
Guide torque converter housing (2) to work surface while
other person operates lifting device.
(8)
Remove lifting device and lifting eyes.
(9)
Turn torque converter housing (2) over using two people.
(10) Remove two seal rings (11) from support hub (12).
b. Disassembly.
NOTE
Discard all old seals and gaskets.
(1)
Set torque converter housing (1) on two wooden
blocks.
CAUTION
When screws are removed, oil pump will fall.
Support oil pump to prevent damage.
(2)
Remove six screws (2) holding oil pump to front
support assembly (3).