TORQUE CONVERTER HOUSING - Continued
TORQUE CONVERTER HOUSING - Continued

Maintenance Manual for Firefighting Truck, 100 Ft Aerial Ladder, 1000 GPM Page Navigation
  274    275    276    277    278  279  280    281    282    283    284  
img
TM 5-4210-233-14&P-2
6-51. TORQUE CONVERTER HOUSING - Continued
WARNING
Parts are under spring tension. Release
tension slowly to prevent personal
injury.
(11) Remove retaining ring (13) while other
person pushes support assembly (14).
NOTE
Tag and mark all parts.
(12) Remove support assembly (14), valve seat
(15), converter bypass valve (16), and spring
(17).
(13) Remove retaining ring (18) while other person
pushes retainer washer (19).
NOTE
Tag and mark all parts.
(14) Remove retainer washer (19), valve stop (20),
valve spring (21), and lockup shift valve (22).
(15) Remove retaining ring (23) while another person
pushes retainer washer (24).
NOTE
Tag and mark all parts.
(16) Remove retainer washer (24), valve stop (25), main
pressure regulator valve spring (26), and main
pressure regulator valve (27).
(17) Remove 15 screws (28) holding front support
assembly (3) to torque converter housing (1).
(18) Remove three screws (29).
(19) Remove screw (30).
6-281