TORQUE CONVERTER PUMP
TORQUE CONVERTER PUMP - Continued

Maintenance Manual for Firefighting Truck, 100 Ft Aerial Ladder, 1000 GPM Page Navigation
  265    266    267    268    269  270  271    272    273    274    275  
img
TM 5-4210-233-14&P-2
6-50. TORQUE CONVERTER PUMP - Continued
(4)
Bend corners of two lockstrips (5) away from heads of
two opposing screws (6).
(5)
Remove two screws (6) from lockstrips (5).
(6)
Install puller (7).
(7)
Tighten puller (7) to separate pump (8) from ground
sleeve (3).
(8)
Remove puller (7).
(9)
Remove pump (8) and set on work surface.
b. Disassembly.
NOTE
Discard old seals when disassembling.
(1)
Bend corners of four lockstrips (1) away from heads of 10
screws (2).
(2)
Remove 10 screws (2) and six lockstrips (1).
6-272