6-6. FIRE PUMP - Continued
(4)
Tag and remove seven copper lines
(1), from manifold drain valve (2).
(5)
Remove roll pin (3) from universal joint
(4) and remove drain valve.
(6)
Remove two bolts (1) securing bracket
(2) to primer valve (3).
(7)
Tag and disconnect wires from priming
pump motor.
(8)
Remove priming tank hose and priming
valve hose.
(9)
Remove five bolts securing priming
pump/motor (see para 4-57).
(10)
Remove priming pump/motor.
(11)
Remove manual pump shift rod,
manual pump shift disengagement
cable, and bracket.
(12)
Remove pump oil pressure gauge line
(4).