STREET SIDE PUMP DISCHARGE MANIFOLD - Continued
STREET SIDE PUMP SUCTION MANIFOLD - Continued

Maintenance Manual for Firefighting Truck, 100 Ft Aerial Ladder, 1000 GPM Page Navigation
  1    2    3    4    5  6  7    8    9    10    11  
img
. . . .
TM 5-4210-233-14&P-2
6-4. STREET SIDE PUMP SUCTION MANIFOLD
This task covers:
a. Removal
c. Follow-on Maintenance
b. Installation
TOOLS REQUIRED
EQUIPMENT CONDITION
Tool Kit, General Mechanics, Automotive
Main Engine Shutdown (see para 2-12.)
(Appendix B, Section III, Item 1)
APU Shutdown (see para 2-16.)
Batteries Disconnected (see para 4-114.)
MATERIALS/PARTS REQUIRED
Tags, identification (Item 32, Appendix E)
Gasket (Figure 31, Appendix F)
Gasket (Figure 16, Appendix F)
a. Removal.
(1)
Remove two nuts (1) and washers (2), and U-bolt (3) from rear auxiliary suction clamp (4).
(2)
Use large pipe wrench to remove pipe (5) from elbow (6).