TM 5-4210-233-14&P-2
6-3. STREET SIDE PUMP DISCHARGE MANIFOLD - Continued
NOTE
Note position of sector gears to install them correctly during
installation.
(4)
Remove eight bolts (5) to remove two valve control assemblies (6) from tops of discharge valves
(7).
NOTE
Leave valve control assemblies connected to actuating linkage.
(5)
Remove four bolts (8) on each valve mounting flange (9). Remove two valves (7) with mounting
flanges (9).
(6)
Turn each valve (7) counterclockwise 1/4 turn and remove them from valve mounting flanges (9).
Remove and discard O-rings (10).
(7)
Disconnect 1 inch hose (10) from tank fill/recirculation valve (11).
(8)
Remove four bolts (12) from #2 crosslay valve (13).
(9)
Remove eight bolts (14) securing discharge manifold (15) to pump body. Remove and discard
gasket (16).
NOTE
Install piping and plugs on new manifold as needed.
b. Installation.
(1)
Using new gasket (16), attach discharge manifold (15) to pump body with eight bolts (14). Torque
to 85 lb ft (115 N.m).
(2)
Using new O-ring, replace four bolts (1 2) to connect #2 crosslay valve (13).
(3)
Reconnect 1 inch hose (1 0) to tank fill/recirculation valve (11).
(4)
Using new O-rings (10), replace two discharge valves (7) and valve mounting flanges (9) (turn
valves 1/4 turn clockwise in valve mounting flanges).
(5)
Tighten four bolts (8) in each valve mounting flange (9) to secure two discharge valves (7).
(6)
Replace two valve control assemblies (6) and attach them to discharge valves (7) with eight bolts
(5).
(7)
Replace two sector gears (4) in same positions they were in prior to removal and secure them with
two roll pins (3).
(8)
Reconnect two pressure gauge hoses (2).
(9)
Reconnect two drain valve hoses (1).
c.
Follow-on Maintenance.
(1)
Connect batteries (see para 4-114).
6-7