- DEPARTMENT OF THE ARMY TECHNICAL MANUAL
- SAFETY PRECAUTIONS
- Direct Support, General Support, and Depot Maintenance Manual
- Figure 1-2. During diagram for model FT.500.
- Figure 2-2. Fire pump, removal and installation for model FT-500.
- Difference in Models
- Figure 3-1A. Water and foam piping and fittings, removal and installation for model FT-500.
- Figure 3-1B. Suction and discharge values, removal and installation for model FT-500.
- Figure 3-2A. Hose real valves, tank fill valve, tank suction valve, and foam metering valve removal and installation for model FT 500.
- Figure 3-4A. Water tank drain valve for model FT-500, exploded view.
- Figure 3-5A. Drain line valve for model FT-500, exploded view.
- Figure 3-6A. Relief valve control for model FT-500, exploded view.
- Figure 3-9A. Primer valve and pump gearbox, removal and installation for model FT-500.
- Difference in Models - continued
- Figure .-16A. Water tank and lines, removal and installation for model FT-500.
- Difference in Models - continued
- Figure 1-2. Wiring diagram for model FT-500.
- Order of the Secretary of the Army
- Table of Contents
- Chapter 1. INTRODUCTION
- Table 1-1. Repair and Replacement Standards
- Chapter 2. GENERAL MAINTENANCE INSTRUCTIONS
- Section III. REMOVAL AND INSTALLATION OF MAJOR COMPONENTS
- Figure 2-1. Suction and discharge heads and screens, removal and installation.
- Chapter 3. REPAIR INSTRUCTIONS
- Drain Line Valve
- Figure 3-1. Water pump, removal and installation.
- Figure 3-1. Water pump, removal and installation - continued
- Figure 3-1. Water pump, removal and installation - continued
- Figure 3-2. Suction valve, exploded view.
- Figure 3-2. Suction valve, exploded view - continued
- Figure 3-3. Hose reel valves, tank fill valve, and tank suction valve, (exploded view.
- Figure 3-3. Hose reel valves, tank fill valve, and tank suction valve, (exploded view) - continued
- Figure 3-4. Water- tank drain valve, exploded view.
- Figure 3-4. Water- tank drain valve, exploded view - continued
- Figure 3-5. Drain line valve, exploded view.
- Figure 3-5. Drain line valve, exploded view - continued
- Figure 3-6. Relief valve control, exploded view.
- Figure 3-6. Relief valve control, exploded view - continued
- Figure 3-7. Foam tank drain valve and foam valve, exploded view.
- Figure 3-8. Foam metering valve, exploded view.
- Section II. PRIMER PUMP ASSEMBLY
- Relief Valve and Adapters
- Figure 3-9. Primer pump assembly, exploded view.
- Figure 3-9. Primer pump assembly, exploded view - continued
- Figure 3-10. Primer valve, exploded view.
- Figure 3-11. Pump gearbox, removal and installation.
- Figure 3-12. Pump gearbox exploded view.
- Figure 3-12. Pump gearbox exploded view - continued
- Figure 3-13. Relief valve and adapter, exploded view.
- Figure 3-13. Relief valve and adapter, exploded view - continued
- Figure 3-14. Pump head and body, exploded view.
- Figure 3-14. Pump head and body, exploded view - continued
- Figure 3-14. Pump head and body, exploded view - continued
- Section IV. HOSE REEL ASSEMBLY
- Figure 3-15. Hose reel assembly, exploded view.
- Figure 3-15. Hose reel assembly, exploded view - continued
- Figure 3-15A. Hose reel motor, exploded view.
- Section V. WATER TANK
- Figure 3-16. Water tank and lines, removal and installation.
- Figure 3-16. Water tank and lines, removal and installation - continued
- Section VI. SPECIAL PURPOSE BODY, WIRING AND DATA PLATES
- Figure 3-18. Special purpose body compartments, removal and installation.
- Chassis Wiring Harness, Replacement
- Appendix A. REFERENCES
- Index
- Figure 1-1. Wiring diagram
- The Metric System and Equivalents
- TM-5-4210-213-35
- Shared Top Border
- Distribution
- Blank Page
- Distribution
- Shared Bottom Border
- RECOMMENDED CHANGES TO EQUIPMENT TECHNICAL PUBLICATIONS
- Shared Left Border
|