CHAPTER 1
INTRODUCTION
Section I. GENERAL
U. S. Army Mobility Equipment Command, ATTN:
1-1. Scope
AMSME-MPP, 4300 Goodfellow Boulevard, St. Louis,
a. These instructions are published for the use of
Mo. 63120.
direct and general support and depot maintenance
personnel maintaining the Model M45A2WLF Ward
LaFrance Fire Fighting Truck. They provide information
c. Report
all
equipment
improvement
on the maintenance of the equipment, which is beyond
recommendations as prescribed by TM 38-750.
the scope of the tools, equipment, personnel, or supplies
normally available to the using organizations.
1-2. Record and Report Forms
b. Report
of
errors,
omissions,
and
For other record and report forms applicable to direct
recommendation for improving this publication by the
and general support, and depot maintenance, refer to
individual user is encouraged.
Reports should be
TM 38-750.
submitted on DA Form 2028 (Recommended Changes
Note: Applicable forms, excluding Standard Form
to DA Publications) and forwarded direct to
46 (United States Government Motor Vehicles
Commanding General,
Operator's Identification Card) which is carried by the
operator, will be kept in a canvas bag mounted on the
equipment.
Section II. DESCRIPTION AND TABULATED DATA
1-3. Description
b. Primer Pump.
A general description of the Ward LaFrance Model
Suction side pump....................
3/4 in. diameter
M45A2WLF Fire truck, the location and description of
Discharge pipe ........................ 1 15/16 in. diameter
the identification and instruction plates, and information
c. Fire Pump.
on the differences in models are contained in the
Relief valve regulator limit 250 psi (pounds per square
Operator and Organizational Maintenance Manual.
inch)
Direct and general support and depot repair and
Related capacity maximum
maintenance instructions are described in appropriate
500 gpm (gallons per minute)
sections of this manual. For truck engine and chassis
Type ...................................................... Centrifugal
maintenance instructions refer to TM 9-2320-209-35.
Pump ratio ............................................ 1 to 2:28
Shaft diameter ......................................
1 1/2 in.
1-4. Tabulated Data
Taper per foot .......................................
1 7/8 in.
a. General.
This paragraph contains all the
overhaul data pertinent to direct and general support
d. Nut and Bolt Torque Data.
and depot maintenance personnel. A wiring diagram
Size
Torque lb. inch
5/16.............................................................. 30
1
3/8 ..............................................................215
7/16.............................................................. 75
3
1/2 ..............................................................300
1-1
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |