NOTE
It may be necessary to re-twist and straighten bus wires.
47. Insert heat trace cable bus wires (5) in guide tubes (38).
48. Push core sealer (8) on heat trace cable (10) to mark made in Step (46).
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
TFFT00975
49. Remove guide tubes (38) and discard.
50. Slip tube (9) on heat trace braid (7). Heat shrinking is not required.
51. Trim heat trace cable bus wires (5) and braid (7) so there is 0.5 in. (13 mm) of exposed wire and heat trace
braid.