DRAFT
TM 5-4210-249-13&P-4
0607
FIELD LEVEL MAINTENANCE
PLUMBING INSULATION REPLACEMENT
INITIAL SETUP:
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Tools and Special Tools
Equipment Conditions
Tool Kit, General Mechanic's: Automotive
Water pump engine OFF (WP 0022)
(WP 0622, Item 27)
Engine OFF (TM 9-2320-347-10)
Wheels chocked (TM 9-2320-347-10)
Materials/Parts
Adhesive, Armacell 520 (WP 0625, Item 1)
Insulation, Armacell, Armaflex
(WP 0625, Item 29)
REMOVAL
TFFT00675
CAUTION
Do not cut heat tape when removing insulation from plumbing. Damage to
electrical wires in heat tape may occur.
NOTE
If reusing original insulation, do not cut along glued seam when cutting insulation off of
plumbing.
Use a very sharp long blade knife to cut insulation.
Make long strokes with knife for best results.
The cut must be clean and not ragged for best results when gluing back together.
1.
Cut insulation (1) with knife.
2.
Remove insulation (1) from plumbing (2).
END OF TASK
0607-1