DRAFT
TM 5-4210-249-13&P-3
FIELD LEVEL MAINTENANCE
PUMP HOUSE WIRE HARNESS REPLACEMENT
INITIAL SETUP:
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Tools and Special Tools
References
Tool Kit, General Mechanic's: Automotive
WP 0010
(WP 0622, Item 27)
WP 0615, Fig. 95
Materials/Parts
Equipment Conditions
Tags, Identification (WP 0625, Item 51)
Pump house panels G, I, O, Q, and S
Ties, Cable, Plastic (WP 0625, Item 58)
Compound, Sealing (WP 0625, Item 17)
Lockwasher (8)
Locknut (2)
Pump operator's panel housing
Lockwasher (6)
REMOVAL
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
TFFT03263
NOTE
Tag and mark connectors and wires prior to removal to ensure proper installation.
Note position and remove cable ties, split looms, and cushion clips as required.
Note routing of wire harness prior to removal to ensure proper installation.
1.
Open passenger side pump house access door (1) (WP 0010).
2.
Disconnect passenger side drain work light connector (2) from pump house wire harness connector (3).
0458-1