PUMP HOUSE POWER DISTRIBUTION WIRE HARNESS AND BLOCK REPLACEMENT - Continued
PUMP HOUSE POWER DISTRIBUTION WIRE HARNESS AND BLOCK REPLACEMENT - Continued

Maintenance Manual For Tactical Fire Fighting Truck (Tfft) Model M1142 - 3 Page Navigation
  698    699    700    701    702  703  704    705    706    707    708  
img
DRAFT
TM 5-4210-249-13&P-3
0457
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
TFFT03057
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
WARNING
ICON 30, 44, 27
Adhesives, solvents, and sealing compounds can burn easily, can give off harmful
vapors, and are harmful to skin and clothing. To avoid injury or death, keep away
from open fire and use in well-ventilated area. If adhesive, solvent, or sealing
compound gets on skin or clothing, wash immediately with soap and water.
4.
Apply silicone sealant to pump house power distribution wire harness connector DP1 (12).
5.
Install pump house power distribution wire harness connector DP1 (12) on power distribution box (15) with
lockwasher (17) and nut (16).
6.
Apply silicone sealant to pump house power distribution wire harness connector DP2 (10).
7.
Install pump house power distribution wire harness connector DP2 (10) on power distribution box (15) with
lockwasher (14) and nut (13).