DRAFT
TM 5-4210-249-13&P-3
0457
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
TFFT03056
8.
Connect pump house wire harness connector (11) on pump house power distribution wire harness connector
DP1 (12).
9.
Connect pump house wire harness connector (9) on pump house power distribution wire harness connector
DP2 (10).
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
TFFT03055
10. Install five wires 1138 (7) on pass-through terminal block (8) with lockwasher (6) and nut (5).
11. Install wire 1640 (3) on pass-through terminal block (4) with lockwasher (2) and nut (1).
END OF TASK
FOLLOW-ON MAINTENANCE
END OF TASK
END OF WORK PACKAGE
0457-6