POWER DISTRIBUTION BOX (PUMP HOUSE) REPLACEMENT - Continued
POWER DISTRIBUTION BOX CONTROL PANEL (PUMP HOUSE) REPLACEMENT - Continued

Maintenance Manual For Tactical Fire Fighting Truck (Tfft) Model M1142 - 3 Page Navigation
  386    387    388    389    390  391  392    393    394    395    396  
img
. . . . . .
DRAFT
TM 5-4210-249-13&P-3
0408
FIELD LEVEL MAINTENANCE
POWER DISTRIBUTION BOX CONTROL PANEL (PUMP HOUSE) REPLACEMENT
INITIAL SETUP:
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Tools and Special Tools
Equipment Conditions
Tool Kit, General Mechanic's: Automotive
Pump house panel S removed (WP 0540)
(WP 0622, Item 27)
Preheat breaker removed (WP 0391)
Auto fill control removed (WP 0363)
Materials/Parts
Terminal block (pass-through)
Lockwasher (1)
removed (WP 0429)
Lockwasher (1)
Dual governor pressure switch
removed (WP 0386)
References
WP 0615, Fig. 83
REMOVAL
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
TFFT02563
NOTE
Note position of connectors before removal to ensure proper installation.
1.
Disconnect main wire harness connector (1) from power distribution panel connector (2).
2.
Disconnect pump panel wire harness connector (3) from power distribution panel connector (4).
3.
Remove nut (5), lockwasher (6), and power distribution panel connector (2) from power distribution box (7).
Discard lockwasher.
4.
Remove nut (8), lockwasher (9), and power distribution panel connector (4) from power distribution box (7).
Discard lockwasher.
0408-1