DRAFT
TM 5-4210-249-13&P-3
FIELD LEVEL MAINTENANCE
DUAL GOVERNOR PRESSURE SWITCH REPLACEMENT
INITIAL SETUP:
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Tools and Special Tools
References
Tool Kit, General Mechanic's: Automotive
WP 0615, Fig. 43
(WP 0622, Item 27)
Equipment Conditions
Materials/Parts
Pump operator's panel housing
Tags, Identification (WP 0625, Item 51)
Locknut (2)
REMOVAL
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
TFFT04455
NOTE
Tag and mark connectors prior to removal to ensure proper installation.
1.
Disconnect dual governor pressure switch power supply connector (1) from pump operator's panel wire
harness connector (2).
2.
Disconnect dual governor pressure switch connector (3) from main wire harness connector (4).
3.
Disconnect dual governor pressure switch connector (5) from pump operator's panel wire harness
connector (6).
0386-1