TM 5-4210-249-13&P-3
0336
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
WARNING
ICON 30, 44, 27
Adhesives, solvents, and sealing compounds can burn easily, can give off harmful
vapors, and are harmful to skin and clothing. To avoid injury or death, keep away
from open fire and use in well-ventilated area. If adhesive, solvent, or sealing
compound gets on skin or clothing, wash immediately with soap and water.
14. Apply sealing compound to two governor control pressure transducers (2), output pressure transducer (4),
and input pressure transducer (6).
15. Install input pressure transducer (6) on tee (14).
16. Install output pressure transducer (4) on tee (13).
17. Install tee (11) on tee (12).
18. Install two governor control pressure transducers (2) on elbow (10) and tee (11).
19. Install two air lines (7) on elbows (8) and (9).
20. Connect connector (5) on input pressure transducer (6).
21. Connect connector (3) on output pressure transducer (4).
22. Connect two connectors (1) on governor control pressure transducers (2).
END OF TASK
FOLLOW-ON MAINTENANCE
1.
Close pump operator's panel housing (WP 0325)
2.
Connect batteries (TM 9-2320-325-14&P)
END OF TASK
END OF WORK PACKAGE