PUMP OPERATOR'S PANEL TEST GAUGE PANEL REPLACEMENT - Continued
PUMP OPERATOR'S PANEL TEST GAUGE PANEL REPLACEMENT - Continued

Maintenance Manual For Tactical Fire Fighting Truck (Tfft) Model M1142 - 3 Page Navigation
  148    149    150    151    152  153  154    155    156    157    158  
img
DRAFT
TM 5-4210-249-13&P-3
0336
INSTALLATION
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
WARNING
ICON 30, 44, 27
Adhesives, solvents, and sealing compounds can burn easily, can give off harmful
vapors, and are harmful to skin and clothing. To avoid injury or death, keep away
from open fire and use in well-ventilated area. If adhesive, solvent, or sealing
compound gets on skin or clothing, wash immediately with soap and water.
1.
Apply sealing compound to threads of three elbows (8), (9), and (10), two fittings (20) and (21), nipples (22)
and (23), and plugs (24).
2.
Install two plugs (24) on test gauge panel (18).
NOTE
Install elbows, fittings, and tees as noted prior to removal.
3.
Install nipple (23) on tee (11).
4.
Install elbow (10) on tee (11).
5.
Install two tees (12) and (13) on nipple (22).
6.
Install elbow (8) on tee (12).
7.
Install fitting (21) on tee (13).
8.
Install fitting (21) on test gauge panel (18).
9.
Install fitting (20) on tee (14).
10. Install elbow (9) on tee (14).
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -