• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
PUMP OPERATOR'S PANEL TEST GAUGE PANEL REPLACEMENT
PUMP OPERATOR'S PANEL TEST GAUGE PANEL REPLACEMENT - Continued

Maintenance Manual For Tactical Fire Fighting Truck (Tfft) Model M1142 - 3 Page Navigation
  145    146    147    148    149  150  151    152    153    154    155  
img
DRAFT
TM 5-4210-249-13&P-3
0336
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
TFFT02344
NOTE
Note position of pressure transducers prior to removal to ensure proper installation.
5.
Remove two governor control pressure transducers (2) from elbow (10) and tee (11).
NOTE
Note position of elbows, fittings, and tees prior to removal to ensure proper installation.
6.
Remove tee (11) from tee (12).
7.
Remove output pressure transducer (4) from tee (13).
8.
Remove input pressure transducer (6) from tee (14).
9.
Remove screw (15), lockwasher (16), and retainer (17) from test gauge panel (18). Discard lockwasher.
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -